Product Highlights

  • Intelligent PLC Control: Features intelligent control with PLC and remote monitoring via RS485 or Ethernet.
  • One-Key Load/Unload: Allows preset power loading to avoid fluctuations during power changes.
  • Comprehensive Protection: Includes emergency stop, overvoltage, short circuit, overheating, and fan interlock protection.
  • Real-time Data Monitoring: Displays voltage, current, power, frequency, and power factor in real-time.
  • Flexible Voltage Options: Supports single voltage 220-690V and multi-voltage configurations like 127/220V.
  • Global Warranty Coverage: Standard 1-year or 1000-hour warranty with optional extended service up to 5 years.
  • Graphical Data Analysis: Software supports printing curves and graphs for voltage, current, power, and frequency.
  • Customizable Service: Provides customized services tailored to specific customer requirements.

Product Images of Resistive Reactive Load Bank for Diesel Generator Testing

Resistive Reactive Load Bank for Diesel Generator Testing pictures & photos
Resistive Reactive Load Bank for Diesel Generator Testing
Resistive Reactive Load Bank for Diesel Generator Testing pictures & photos
Resistive Reactive Load Bank for Diesel Generator Testing
Resistive Reactive Load Bank for Diesel Generator Testing pictures & photos
Resistive Reactive Load Bank for Diesel Generator Testing
Resistive Reactive Load Bank for Diesel Generator Testing pictures & photos
Resistive Reactive Load Bank for Diesel Generator Testing
Resistive Reactive Load Bank for Diesel Generator Testing pictures & photos
Resistive Reactive Load Bank for Diesel Generator Testing
Resistive Reactive Load Bank for Diesel Generator Testing pictures & photos
Resistive Reactive Load Bank for Diesel Generator Testing
  • Resistive Reactive Load Bank for Diesel Generator Testing
    Resistive Reactive Load Bank for Diesel Generator Testing
  • Resistive Reactive Load Bank for Diesel Generator Testing
    Resistive Reactive Load Bank for Diesel Generator Testing
  • Resistive Reactive Load Bank for Diesel Generator Testing
    Resistive Reactive Load Bank for Diesel Generator Testing
  • Resistive Reactive Load Bank for Diesel Generator Testing
    Resistive Reactive Load Bank for Diesel Generator Testing
  • Resistive Reactive Load Bank for Diesel Generator Testing
    Resistive Reactive Load Bank for Diesel Generator Testing
  • Resistive Reactive Load Bank for Diesel Generator Testing
    Resistive Reactive Load Bank for Diesel Generator Testing

Find Similar Products

Product Description

Resistive Reactive Load Bank for Diesel Generator Testing

Options:

1. Single voltage:  220-690V
2. Multive voltage: 127/220V, 220/380V, 230/400V, 240/415V, 277/480V
3. Intelligent control with PLC
4. Remote control or monitoring via RS485 or Ethernet
5. Trailer mounted
6. 20-5000kw


Measuring Function
--Load testing: Can load power within rated power, test and display stable state 3 phases voltage, current, active power, frequency, working time, etc of generator sets.
--Load/unload with one key: Whether manual control or intelligent control, the user can preset power, then press the loadmaster button. Load bank will load according to preset power to avoid load fluctuation during the power changing.
--Control pattern: User can choose local control and intelligent control.
--Local control: There is a local control panel with several power steps; the user can load/unload by button.
--Intelligent control: Through data processing software in PC, users can make automatic load, display, record, and manage the testing data, form curves, tables, also to print them.
--Control pattern interlock: There is a control pattern switch, when choosing one control pattern, the operation of the other pattern is invalid, avoids the clash.
--Local meter display data: Local meter can display 3 phases voltage, current, active power, frequency.

Protection
--Emergency stop: The user can press the Emergency Stop switch in the panel, when the load bank is locked in this state, it can't add any load.  
--Overvoltage protection: When the input voltage is over the safety value, it will unload automatically and give an alarm.
--Short circuit protection: When a short circuit occurs, the load bank will unload automatically.
--Overheating protection: When the temperature is over the safety threshold, it will unload automatically and give an alarm.
--Fan interlock protection: Load bank can't add any load before working power on.
--Protection Buttons: There are buttons for some protection, when misinformation occurs or the user has special needs, the user can temporarily turn off the corresponding protection function.


Software Function
--Communication pattern: Intelligent control use photoelectric isolated RS485 interface connect to PC, with great anti-interference performance to make system control stable. Also, users can use USB or RS232 through the converter.  
--Load pattern: Manual Load or Automatic Load.
--Manual Load: Input power, the system will load according to preset power.
--Automatic load: user can preset power and length of working time of several load periods, as per 0%→25%→50%→75%→100% or 110% to make testing.
--Real-time parameter: through software to display real-time voltage, current, power, power factor, frequency and time, etc.
--Security monitoring and control: monitor the working state of the load bank by watching software light, when abnormally stop and in protection status, it will show the reason.
--Data collection interval: the minimum storage for the interval is 2 seconds.
--Data save and the query: all the test data is saved in the software, easy to query in the history testing data.
--Graphical display: show real-time or history testing data, and support to print curve and graph as follows:
1) Graphs of real-time voltage, current, frequency, and power;
2) Voltage graph

3) Current graph
4) Power graph
5) Frequency graph
6) Power factor graph


Resistive Reactive Load Bank for Diesel Generator Testing

Resistive Reactive Load Bank for Diesel Generator Testing
Resistive Reactive Load Bank for Diesel Generator Testing
1. Why Choose us?
Vigkoo has a wide range of cooperative supplier groups. Whether you need to find which power equipment products, Vigkoo can help you quickly enter the Chinese supply system and obtain the latest market products and competitive prices.

2. Delivery Time?
Spare parts about 3-5 days.Diesel generator set about 30-50 days.

3. Manufacturer or Trade Company?
We have our own factory for OEM manufacture producing, also trade with all electrical parts.

4. Global Warranty?
Yes, usually global warranty 1 year / 1000 hours.Provide extended warranty service for 2 years / 2000 hours, 3 years, 5 year ... ...

5. Payment terms?
L/C,  T/T,  Western Union,  PayPal

6. Customized service?
Provide customized services according to the customer requirements
 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR237369". Items marked "verified" are certified.

Watch Video
Watch Video
DIY Power System Co., Ltd.
DIY Power System Co., Ltd.
DIY Power System Co., Ltd.
DIY Power System Co., Ltd.
DIY Power System Co., Ltd.
DIY Power System Co., Ltd.
DIY Power System Co., Ltd.
DIY Power System Co., Ltd.

About Our Factory & Business Background

Address
12th/F, No. 2 Geospace Building, 15 Gaoxin Avenue, Minhou High-Tech Zone, Fuzhou City, Fujian, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF
Nearest Port
Fuzhou

Our Production Capability & Technical Expertise

Main Products
Silent Generator, Generator Spare Parts, Diesel Generator Set, ATS, Light Tower

Our Industry Experience & Global Business Record

Export Year
2020-03-10
Main Markets
South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the delivery time for spare parts and diesel generator sets?
Spare parts take about 3-5 days, while diesel generator sets take 30-50 days.
Is Vigkoo a manufacturer or a trade company?
We have our own factory for OEM manufacturing and also trade in all electrical parts.
What is the warranty period for the product?
We provide a standard global warranty of 1 year or 1000 hours, with options for 2, 3, or 5 years.
What payment terms do you accept?
We accept L/C, T/T, Western Union, and PayPal.
Do you offer customized services?
Yes, we provide customized services according to customer requirements.
What measuring functions does the load bank support?
It can test and display stable state 3-phase voltage, current, active power, frequency, and working time.
How does the intelligent control system work?
Users can make automatic load, display, record, and manage testing data via PC software with RS485 or Ethernet connection.
What protection features are included?
It includes emergency stop, overvoltage, short circuit, overheating, and fan interlock protection.