Customization: | Available |
---|---|
Phase: | Three Phase |
Type: | Modular UPS |
Still deciding? Get samples of US$ 100/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Modular design, including power module, bypass module, monitoring module, which means it can be easily integrated in MDC or customized cabinet. |
Flexible power module: 10/15/20/25/30kVA ((2U)) |
High input power factor, it is up to 0.99. |
Width input voltage range:line voltage range is 138-485V, UPS would be derating when input voltage is below 305V. |
Parallel redundant configurations:failure of one module will not impact system or site operation. |
Three level topology design, efficiency is up to 95.8%. |
Sleeping Mode to save energy. |
Support parallel expanded operation: maximum is 6 units, Support sharing batteries for the UPS in parallel. |
Technical Specification
Module Model | HPM3300E-RM-10 | |||
Cabinet Model | HPM3300E-20 | HPM3300E-40 | HPM3300E-60 | |
Cabinet capacity (VA) | 10k~20k | 10k~40k | 10k~60k | |
Module capacity (VA) | 10k | |||
Max. Number | 2 | 4 | 6 | |
Module Model | HPM3300E-RM-15 | |||
Cabinet Model | HPM3300E-30 | HPM3300E-60 | HPM3300E-90 | |
Cabinet capacity (VA) | 15k~30k | 15k~60k | 15k~90k | |
Module capacity (VA) | 15k | |||
Max. Number | 2 | 4 | 6 | |
Module Model | HPM3300E-RM-20 | |||
Cabinet Model | HPM3300E-40 | HPM3300E-80 | HPM3300E-120 | |
Cabinet capacity (VA) | 20k~40k | 20k~80k | 20k~120k | |
Module capacity (VA) | 20k | |||
Max. Number | 2 | 4 | 6 | |
Module Model | HPM3300E-RM-25 | |||
Cabinet Model | HPM3300E-50 | HPM3300E-100 | HPM3300E-150 | |
Cabinet capacity (VA) | 25k~50k | 25k~100k | 25k~150k | |
Module capacity (VA) | 25k | |||
Max. Number | 2 | 4 | 6 | |
Module Model | HPM3300E-RM-30 | |||
Cabinet Model | HPM3300E-60 | HPM3300E-120 | HPM3300E-150 | |
Cabinet capacity (VA) | 30k~60k | 30k~120k | 30k~150k | |
Module capacity (VA) | 30k | |||
Max. Number | 2 | 4 | 5+1 | |
INPUT | ||||
Nominal voltage | 380/400/415Vac, (3Ph+N+PE) | |||
Operating voltage range | 138~305Vac for 40% Load; 305~485Vac for 100% Load; | |||
Operating frequency range | 40Hz-70Hz | |||
Power factor | ≥0.99 | |||
Harmonic distortion (THDi) | ≤3% (100% linear load) | |||
Bypass voltage range | Max. voltage:220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%) | |||
Min. voltage: -45% (optional-10%, -15%, -20%, -30%) | ||||
Bypass frequency range | Frequency protection range: ±10% | |||
Power Walk In | Support | |||
Generator input | Support | |||
OUTPUT | ||||
Rated voltage | 380/400/415Vac, (3Ph+N+PE) | |||
Power factor | 1 | |||
Voltage regulation | ±1% | |||
Output frequency | Line Mode | Synchronize with input, when the input frequency >±10%(±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz) | ||
Bat. Mode | (50/60±0.1%)Hz | |||
Crest factor | 3:01 | |||
Harmonic distortion (THDv) | ≤1% with linear load; ≤3% with nonlinear load | |||
Efficiency | up to 95.8% | |||
BATTERY | ||||
Battery voltage | Optional Voltage: ±180/192/204/216/228/240/252/264/276/288/300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs optional); | |||
360Vdc~600Vdc (30~50 pcs, 36 pcs default, 36~50 pcs no power derating; 32~34 pcs output power factor 0.9; 30 pcs output power factor 0.8) | ||||
Power module charge current | 18A (Max.) | |||
SYSTEM FEATURES | ||||
Transfer time | Utility to Battery : 0ms; Utility to bypass: 0ms | |||
Overload | Line Mode | ≤110%, 60min; ≤125%, 10min; ≤150%,1min; to bypass.>150% Shut down Immediately. | ||
Bypass Mode | 135% overload for long term; >1000% overload for 100 ms | |||
Overheat | Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately | |||
Low battery voltage | Alarm and Switch off | |||
Self-diagnostics | Upon Power On and Software Control | |||
Backfeed | Support | |||
EPO | Shut down UPS immediately (turn to bypass optional) | |||
Battery | Advanced Battery Management | |||
Noise suppression | Complies with EN62040-3 | |||
Audible & Visual alarms | Line Failure, Battery Low, Overload, System Fault | |||
Status LED & LCD display | Line Mode, Bypass Mode, Battery Low, Battery Fault, Overload & UPS Fault | |||
Reading on the LCD display | Input, Output, Battery, Command, Setting, Maintenance | |||
Communication interface | RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card(optional), SNMP card(optional), Battery temperature sensor(optional) | |||
ENVIRONMENTAL | ||||
Operating temperature | 0ºC~40ºC | |||
Storage temperature | -25ºC~55ºC | |||
Humidity range | 0~95% (non condensing) | |||
Altitude | <1500m, derating required when >1500m | |||
Noise level(from 1M distance) | <58dB | <60dB | <62dB | |
PHYSICAL | ||||
Dimension W×D×H (mm) | UPS cabinet | 485×850×353(8U) | 485×850×575(13U) | 485×850×752(17U) |
Power module | 440×620×86(2U) | |||
Net weight (kg) | UPS cabinet | 69 | 79 | 98 |
Power module | 10kVA: 19; 15~30kVA: 21 | |||
STANDARDS | ||||
Safety | IEC/EN62040-1, IEC/EN62477-1 | |||
EMC | IEC/EN62040-2 (IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8) | |||
Specifications are subject to change without prior notice. |