Customization: | Available |
---|---|
Task: | Program |
Structure: | Combination |
Still deciding? Get samples of US$ 150/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ERFORMANCE AND CHARACTERISTICS
HGM6100N controller has six variants:
HGM6110N/6110NC/6110CAN: Automatic Start Module, it controls generator to start/stop by remote start signal;
HGM6120N/6120NC/6120CAN: Based on HGM6110N/6110NC/6110CAN, it adds mains AC monitoring and mains/generator automatic switching control (AMF), especially suitable for the automation system composed by mains and genset.
NOTE1: HGM6110NC/6120NC has RS485 port, HGM6110N/6120N without.
HGM6110CAN/6120CAN has CAN port, HGM6110N/6120N and HGM6110NC/6120NC without.
NOTE2: HGM6110/6120 is taken as an example to describe in this manual.
Main characteristics are as following:
132x64 LCD display with backlight, optional language interface (Chinese, English, Spanish, Russian, Portuguese, Turkey, Polish and French), push-button operation;
Acrylic screen, improved wearable and scratch resistance property;
Silica-gel panel and keys can well adapt to higher and lower temperature;
RS485 communication port enables "three remote" functions via MODBUS protocol;
CANBUS port which can be connected to ECU with J1939, it not only can monitor frequently-used data (such as water temperature, oil pressure, speed and fuel consumption, etc.) but also can control start, stop, high speed and low speed (controller with CANBUS port is needed) via CANBUS port;
Adapt to 3P4W, 3P3W, 1P2W and 2P3W (120V/240V), 50Hz/60Hz system;
Can measure and display 3 phase voltage, 3 phase current, frequency, power parameter of mains/gens;
Mains Generator
Line voltage (Uab, Ubc, and Uca) Line voltage (Uab, Ubc, and Uca)
Phase voltage (Ua, Ub, and Uc) Phase voltage (Ua, Ub, and Uc)
Frequency Hz Frequency Hz
Phase sequence Phase sequence
Load
Current IA, IB, IC
Each and total active power kW
Reactive power kvar
Apparent power kVA
Power factor PF
Generator accumulated energy kWh
Output percentage with load %
For mains, genset has functions of over/under voltage and loss of phase; For gens, genset has functions of over/under voltage, over/under frequency, over current and over power;
Precision measure and display of parameters about engine;
Temp. (WT) °C/°F
Oil pressure (OP) kPa/psi/bar
Fuel level (FL) % Fuel remains L
Speed (SPD) r/min
Battery Voltage (VB) V
Charger Voltage (VD) V
Accumulated running hours
Accumulated start times
Control and protection function: Automatic start/stop of genset, load transfer (ATS control) and perfect fault display and protection;
With ETS, idle control, pre-heat control, speed raise/drop control, all of them are relay outputs;
Parameter setting: Allow user to modify setting and store them in internal FLASH memory. The parameters cannot be lost even when power off. All of parameters can be set not only from the front panel, but also adjusted through USB interface (or RS485 interface) via PC;
Multiple sensors of temperature, pressure and fuel level can be used directly, parameters can be defined by user;
Multiple conditions of crank disconnect (speed, oil pressure, frequency) can be selected;
With emergency start function;
With flywheel teeth numbers automatic identification function;
Power supply range: (8~35)VDC, accommodating to different starting battery voltage environment;
All parameters use digital modulation, instead of analog modulation using conventional potentiometer, having improved reliability and stability;
With maintenance function. Types (date or running time) can be selected and actions (warning or alarm shutdown) can be set when maintenance time out;
Event log, real-time clock, scheduled start & stop function (can be set as start unit once a day/week/month whether with load or not);
Add rubber gasket between shell and controller screen, the waterproof can reach IP65;
Controller is fixed by metal fixing clips;
Modular design, flame-retardant ABS shell, pluggable terminal, embedded mounting, compact structure and easy installation.