Customization: | Available |
---|---|
Phase: | Three-Phase and Single Phase |
Type: | On-line |
Still deciding? Get samples of US$ 600/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
True double-conversion |
DSP technology guarantees high reliability |
N+X parallel redundancy |
Compatible with three-phases and single-phase input |
Selectable quantity of battery for each group:16/18/20 pieces |
Adjustable charging current via LCD |
3-stage charging design optimizes battery performance |
ECO mode operation for energy saving |
Self-diagnosis at startup |
Emergency power off function(EPO) |
Maintenance bypass is convenient for maintenance |
Generator compatible |
Communications:RS-232,USB,Parallel card(Optional),SNMP card(Optional), Relay card (Optional) |
Cold start |
Technical Specification | ||||||
MODEL | UC100 | UC100L | UC150L | UC200L | ||
Capacity (VA/Watts) | 10K / 9K | 15K / 13.5K | 20K / 18K | |||
INPUT | ||||||
Nominal Voltage | 380/400/415Vac(3Ph+N+PE) or 220/230/240Vac(L+N+PE) | |||||
Operating | 208~478Vac or 120VAC-276Vac | |||||
Voltage Range | ||||||
Operating | 50Hz:45~55Hz,60Hz:54~66Hz | |||||
Frequency Range | ||||||
Power Factor | ≥0.99 | |||||
Bypass | Max.voltage: 220V:+25%(Optional +10%,+15%,+20% ) | |||||
Voltage Range | 230V:+20%(Optional +10%,+15%) | |||||
240V:+15%(Optional +10% ) | ||||||
Min. voltage: -45% (Optional -20%,-30%) | ||||||
ECO Range | Same as bypass | |||||
Harmonic | ≤5%(100% non-linear load) | |||||
Distortion (THDi) | ||||||
OUTPUT | ||||||
Rated Voltage | 220/230/240Vac | |||||
Power Factor | 0.9 | |||||
Voltage Regulation | ±1% | |||||
Frequency | Line Mode | ±1%/±2%/±4%/±5%/±10% of the rated | ||||
frequency(Optional) | ||||||
Bat. Mode | (50/60±0.1)Hz | |||||
Crest Factor | 3:01 | |||||
Harmonic | ≤2% with linear load | |||||
Distortion (THD) | ≤5% with non-linear load | |||||
Waveform | Pure Sinewave | |||||
Transfer Time | Utility to Battery : 0ms; Utility to Bypass: 0ms | |||||
EFFICIENCY | ||||||
Efficiency | Up to 94% | Up to 94.5% | ||||
BATTERY | ||||||
Battery Voltage | Selectable Voltage: ±96/108/120Vdc | |||||
Typical | 6-8 hours (To 90% capacity) | |||||
Recharge Time | ||||||
Charging Current | Maximum current 10A | |||||
PROTECTION | ||||||
Overload | Line Mode | Load≤125%: last 5min;≤150%: last 1min;>150% 200ms | ||||
turn to bypass mode | ||||||
Bypass Mode | 63A(Input breaker) | 100A(Input breaker) | 125A(Input breaker) | |||
Short Circuit | Hold Whole System | |||||
Overheat | Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately | |||||
Battery Low | Alarm and Switch off | |||||
INDICATORS | ||||||
Audible & | Line Failure, Battery Low, Overload, System Fault | |||||
Visual Alarms | ||||||
Status LED & | Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, | |||||
LCD Display | Battery Bad, Overload & UPS Fault | |||||
Parameters On | Input/Output Voltage, Input/Output Frequency, Load Level, Battery Level, | |||||
The LCD Panel | Inner Temperature & Remaining Battery Backup Time | |||||
MANAGEMENT | ||||||
Communication | RS-232,USB,Parallel card(Optional), SNMP card(Optional), Relay card (Optional) | |||||
Interface | ||||||
ENVIRONMENT | ||||||
Operating Temperature | 0ºC~40ºC | |||||
Storage Temperature | -25ºC~55ºC | |||||
Humidity Range | 0~95% (Non-condensing) | |||||
Altitude | < 1500m | |||||
Noise Level | <55dB | <58dB | ||||
PHYSICAL | ||||||
Dimension | 250×597×655 | 250×502×616 | ||||
W×D×H (mm) | ||||||
Net Weight (kg) | 76 | 35 | 45 | 46 | ||
STANDARDS | ||||||
Noise Suppression | Complies with EN62040-2 | |||||
Safety | IEC/EN62040-1,IEC/EN60950-1 | |||||
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, | |||||
IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |