Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | On-line |
Still deciding? Get samples of US$ 600/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
True double-conversion |
Rack-mounted and floor-standing tower can be convertible |
Patented Mimic LCD of which content can be rotated according to the type of deployment |
Digital control guarantees high reliability |
Output receptacle control for non-critical load shedding capability |
ECO mode operation for energy saving |
Emergency power off function(EPO) |
Generator compatible |
Communications:RS-232,USB,SNMP card(Optional), Relay card (Optional) |
Maintenance bypass is convenient for maintenance |
Bypass can be used when UPS is off(Setted in LCD) |
Cold start |
MODEL | UBR | UBR | UBR | UBR | UBR | UBR | UBR | UBR | UBR | UBR | UBR | UBR | |
10 | 10-36 | 10L | 10L-36 | 15 | 15L | 20 | 20-72 | 20L | 20L-72 | 30 | 30L | ||
Capacity (VA/Watts) | 1000VA/900W | 1500VA/1350W | 2000VA/1800W | 3000VA/2700W | |||||||||
INPUT | |||||||||||||
Nominal Voltage | 208/ 220/230/240Vac(L+N+PE) | ||||||||||||
Operating Voltage | 110~300Vac @(0~60%) Load;120~300Vac @(60~70%)Load | ||||||||||||
Range | 140~300Vac @(70~80%)Load;160~300Vac @(80~100%)Load | ||||||||||||
Operating Frequency | 50Hz:45~55Hz,60Hz: 55-65Hz Auto Sensing | ||||||||||||
Range | |||||||||||||
Power Factor | > 0.85@25%Load;>0.95 @50%Load;>0.97@75%Load;>0.99 @ Nominal voltage& 100%Load | ||||||||||||
OUTPUT | |||||||||||||
Output Voltage | 208/220/230/240Vac:230Vac(Default) | ||||||||||||
Power Factor | 0.9 | ||||||||||||
Voltage Regulation | ±1% | ||||||||||||
Crest Factor | 03:01 | ||||||||||||
Harmonic Distortion | ≤3% with linear load | ||||||||||||
(THDv) | ≤5% with non-linear load | ||||||||||||
Wave form | Pure Sinewave | ||||||||||||
Transfer time | Utility to Battery : 0ms; Utility to Bypass: 4ms(Typical) | ||||||||||||
EFFICIENCY | |||||||||||||
AC Mode | 88% | 88% | 89% | 90% | |||||||||
Battery Mode | 84% | 85% | 84% | 85% | 85% | 85% | 86% | 85% | 86% | 87% | |||
ECO Mode | 94% | ||||||||||||
BATTERY | |||||||||||||
Battery Type | 12V/9AH | 12V/7AH | 12V | 12V/9AH | 12V | 12V/9AH | 12V/7AH | 12V | 12V/9AH | 12V | |||
Numbers | 2 | 3 | 2*N | 3*N | 3 | 3*N | 4 | 6 | 4*N | 6*N | 6 | 6*N | |
Maximum Charging | 1 | 1 | 6.0/12.0 | 1 | 6.0/12.0 | 1 | 1 | 6.0/12.0 | 1 | 6.0/12.0 | |||
Current (A) | |||||||||||||
Charging | 27.4±1% | 41.1±1% | 27.4±1%,41.1±1% | 41.1±1% | 54.8±1% | 82.2±1% | 54.8±1%,82.2±1% |
82.2±1%
|
|||||
Voltage(Vdc) | |||||||||||||
Protect | Over-voltage(14.7v) /Low-voltage(10v) | ||||||||||||
PROTECTION | |||||||||||||
Overload | 105%-150%, 30s turn to bypass mode ; >150% 300ms turn to bypass mode | ||||||||||||
Line Mode | |||||||||||||
Capacity | 105%-150%, exceed 30s shutdown ; >150% exceed 300ms shutdown | ||||||||||||
Battery Mode | |||||||||||||
INDICATORS | |||||||||||||
LED & LCD Display | Load/Battery/Input/Output/Operating Mode Information | ||||||||||||
ALARM | |||||||||||||
Battery Mode | Sounding every 4 seconds | ||||||||||||
Battery Low | Sounding every second | ||||||||||||
Overload | Sounding every 0.5 second | ||||||||||||
Fault | Continuously Sounding | ||||||||||||
MANAGEMENT | |||||||||||||
Smart RS-232/USB | External Modbus card supported by RS232,Software supports Windows Family,Linus,FreeBSD | ||||||||||||
(Preferential) | |||||||||||||
Intelligent Slot | SNMP (Standard or mini) independent to RS-232(Optional) | ||||||||||||
ENVIRONMENT | |||||||||||||
Operating Temperature | 0ºC~40ºC | ||||||||||||
Humidity Range | 0~95% (Non-condensing) | ||||||||||||
Altitude | < 1500m | ||||||||||||
Noise Level | <50dB@ 1Meter | ||||||||||||
PHYSICAL | |||||||||||||
Dimension W×D×H (mm) | 440×430×86.5 | 440×572×86.5 | 440×696×86.5 | 440×572×86.5 | 440×696×86.5 | 440×572×86.5 | |||||||
Net Weight (kg) | 13.2 | 15.7 | 7.7 | 7.8 | 15.8 | 7.9 | 21.5 | 27.6 | 10.7 | 10.8 | 28.5 | 11.2 | |
STANDARDS | |||||||||||||
Safety | IEC/EN62040-1 | ||||||||||||
EMC | IEC/EN62040-2 |